Closed Loop Cooling Tower

Closed Loop Cooling Tower

The SMWA Closed circuit adopts a modular design of forced draft centrifugal fans and air intake on the bottom side.All series has obtained CTI thermal performance certification, and at standard operating conditions, the single-unit water flow rate can range from 30 T/h to 250 T/h.

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction
SMWA Closed Circuit Cooling Towers

 

Description

 

The refrigerant gas discharges from the compressor into the inlet connection of the SMWA closed circuit cooling towers. Heat from the refrigerant dissipates through the coil tubes to the water cascading downward over the tubes. Simultaneously, the air is forced in through the centrifugal fans at the base of the cooling towers and travels upward through the coils, opposite the water flow. A small portion of the water evaporates, removing heat from the system; the saturated hot air is discharged to atmosphere. Cooler water drains to the water basin at the bottom of the cooling tower where it is recirculated by the pump up through the water distribution system and back down over the coils. The vertical air discharge of the SMWA design and the distance between the discharge air and the fan intake reduce the chance of air recirculation since the warm humid air is directed up and away from the cooling towers.

product-500-375

cooling Process

 

SMWA

 

Detailed information for Cooling Tower Parts

 

Cooling Tower Casing

Available with HDG steel and stainless steel material based on the customer's request.

product-600-468

Cooling Tower Drift Eliminator

This cooling tower drift eliminator is produced by 100% raw material, this drift eliminators is the cellular type. The eliminators incorporate three changes in air direction to assure removal of entrained moisture from the discharge airstream. The maximum drift rate does not exceed 0.0005% of the recirculated water rate.

The drop eliminators shall be constructed of inert polyvinyl chloride (PVC) that has been specially treated to resist UV degradation.
The drift eliminators are available without frame, with FeZn frame or with AISI304 frame depending on the existing unit structure.
The eliminators are assembled in easily handled sections and guaranteed to fit your evaporative cooling equipment.
 

Cooling Tower Water Distribution System

TJLATINO use the non-clog cooling tower nozzle for this SMWA cooling towers, it can provide even and constant water distribution, and best performing non-corrosive, maintenace-free water distribution system.

 

Cooling Tower Coil

Elliptical return bends allows for more circuits per coil bunble increasing the max. catacity per footprint;

Coil located in airstream increasing ambient dry bulb switchover temperature;

Available with SS304 & SS316 material.

product-348-325

 

Factory Corner

 

20241009155218
20241009155208
20241009155229

 

Projects

 

3
 
1
 
4
 
2
 

 

Shipments
6001
01.

Container shipment

For the cooling tower size which suitable for container loading, we will load the container with several parts based on size for 20gp and 40hc .

02.

Special sea shipment

For the bigger cooling tower, we also could make the shipment by flat rack container. And our packing department have much experiences for the cooling tower fixing when loading.

6005

Hot Tags: closed loop cooling tower, China closed loop cooling tower manufacturers, suppliers, factory, industrial cooling repair, heat rejection system, reliable condenser, condenser replacement, process cooling solution, evaporative heat exchanger

You Might Also Like

(0/10)

clearall